The Eautonome Ontology

Metadata

IRI
https://w3id.org/eautonome
Creator
Erdem Önal Orcid logo ( erdem.onal@enpc.fr ) of École nationale des ponts et chaussées
Imports
http://www.w3.org/ns/sosa/
https://saref.etsi.org/saref4watr/v2.1.1/
See also
Eautonome project homepage
W3C SOSA/SSN Usage Report
License
CC BY 4.0
Version
1.0.1 (owl:versionIRI)
Publisher
Laboratoire Eau, Environnement et Systèmes Urbains (Leesu)
Download serialization
JSON-LD, RDF/XML, N-Triples, TTL
Example data
Hydrodynamic observations
Shower observations

Description

The Eautonome Ontology provides an OWL representation of residential water end-use monitoring. It models domestic water uses, quality levels, and greywater reuse processes to reduce water consumption in residential buildings.

Overview

The Eautonome Ontology describes physical water infrastructure and monitoring devices in a residential observation system. These components generate observations related to domestic water use and water quality.

The ontology represents the greywater recycling infrastructure, the sensor network, and the resulting observations. It supports queries over domestic water use events, sensor status, measurement locations, pipe configurations, and greywater reuse data.

Competency Questions

Queries

IDNatural language questionExample
Q1Which sensor made the observation?The physical device that generated the data. For example, <eau:obsFlowHeaterOutput20260627T034633> is made by <eau:flowmeterHeaterOutput>.
Q2What physical property is measured?For example, <s4watr:FlowRate> or <s4watr:Conductivity>.
Q3Where is the measurement point located and which asset does it measure?For example, <eau:mpBathroomHot> is located in <eau:roomBathroom> and measures <eau:pipeBathroomHot>.
Q4What is the result of the observation?For example, a flow result may be expressed in <unit:L-PER-MIN>.
Q5What is the timestamp of the observation?For example, "2026-06-27T03:46:33+02:00"^^xsd:dateTime.
Q6What is the operational status of each device?For example, <eau:flowmeterBathroomCold> is inactive.
Q7Which temporal extent and usage activity characterize an observation collection?The temporal extent is represented with sosa:phenomenonTime and OWL-Time, and the activity is linked through eau:hasConsumptionEvent.
Q8Which procedure is used to acquire the observation?ADC sensors use <eau:eautonomeObservingProcedure>; the connected shower sensor uses <eau:showerObservingProcedure>.
Q9Which sensors have recorded calibration parameters, and what are they?For example, <eau:flowmeterHeaterOutput> has a calibration slope of 0.957 and an R2 value of 0.9988.

Additional Queries

IDNatural language questionExample
Q10Which sensors are included in the deployment?The query follows sosa:deployedSystem from <eau:eautonomeDeployment> and returns 14 sensors.
Q11Which room is associated with an observation?The room is obtained from the observation's measurement point through eau:locatedIn.
Q12Which measurement points are at operational risk?Four measurement points are monitored by a sensor whose status is inactive or planned.
Q13Which observations belong to the same collection and consumption event?sosa:hasMember links observations to a collection, while eau:hasConsumptionEvent links the collection to the corresponding water use event.

SPARQL Examples

The following SPARQL queries are examples from the evaluation. All counts below were obtained over the published ontology and the two example observation datasets.

PREFIX eau: <https://w3id.org/eautonome/>
    PREFIX sosa: <http://www.w3.org/ns/sosa/>
    PREFIX s4watr: <https://saref.etsi.org/saref4watr/>
    PREFIX rdfs: <http://www.w3.org/2000/01/rdf-schema#>

Q3

SELECT ?mp ?room ?asset WHERE {
      ?mp a eau:MeasurementPoint ;
          eau:locatedIn ?room ;
          eau:measuresOnAsset ?asset .
    }
    ORDER BY ?mp

Result: 10 measurement points.

Q9

SELECT ?sensor ?slope ?r2 WHERE {
      ?sensor a ?sensorClass .
      ?sensorClass rdfs:subClassOf* sosa:Sensor .
      ?sensor eau:hasCalibrationSlope ?slope ;
              eau:hasCalibrationR2 ?r2 .
    }
    ORDER BY ?sensor

Result: 6 sensors with recorded calibration slope and R2.

Q10

SELECT DISTINCT ?sensor WHERE {
      eau:eautonomeDeployment sosa:deployedSystem ?sensor .
      ?sensor a ?sensorClass .
      ?sensorClass rdfs:subClassOf* sosa:Sensor .
    }
    ORDER BY ?sensor

Result: 14 sensors.

Q12

SELECT DISTINCT ?mp WHERE {
      ?sensor eau:monitors ?mp ;
              eau:hasOperationalStatus ?status .
      FILTER(?status IN ("inactive", "planned"))
    }
    ORDER BY ?mp

Result: 4 measurement points.

Classes

Analog to digital converter c # Classes

URIhttps://w3id.org/eautonome/ADConverter
Description

A component for converting analog sensor signals into digital data.

Super-classessosa:Platform
sosa:System
Memberseau:adcCard1
eau:adcCard2

Conductivity and temperature sensor c # Classes

URIhttps://w3id.org/eautonome/ConductivityTemperatureSensor
Description

A sensor measuring both the electrical conductivity and temperature of water.

Super-classess4watr:WaterDevice
sosa:Sensor
Memberseau:jumoDigiLineBoiler
eau:jumoDigiLineShower

Consumption event c # Classes

URIhttps://w3id.org/eautonome/ConsumptionEvent
Description

A domestic water use activity. It complements sosa:phenomenonTime on observation collections.

Super-classesschema:Event
Memberseau:eventAfternoonShower20260628
eau:eventEveningShower20260627

Domestic room c # Classes

URIhttps://w3id.org/eautonome/DomesticRoom
Description

A room in a dwelling in which water consumption or collection occurs.

Super-classessosa:FeatureOfInterest
Memberseau:roomBasement
eau:roomBathroom
eau:roomGarden
eau:roomKitchen
eau:roomToilet

Eautonome observing procedure c # Classes

URIhttps://w3id.org/eautonome/EautonomeObservingProcedure
Description

Data acquisition via ADC on the Raspberry Pi.

Super-classessosa:ObservingProcedure
Sub-classeseau:ShowerObservingProcedure
Memberseau:eautonomeObservingProcedure
eau:showerObservingProcedure

Greywater recycling system c # Classes

URIhttps://w3id.org/eautonome/GreywaterRecyclingSystem
Description

A system for collecting, treating, and redistributing domestic greywater.

Super-classess4watr:WaterInfrastructure
sosa:Platform
Memberseau:eautonomeSystem

Measurement point c # Classes

URIhttps://w3id.org/eautonome/MeasurementPoint
Description

A location within the water infrastructure at which observations are made.

Super-classess4watr:WaterAsset
sosa:FeatureOfInterest
Memberseau:mpBasementCold
eau:mpBathroomCold
eau:mpBathroomHot
eau:mpHeaterOutput
eau:mpKitchenCold
eau:mpKitchenHot
eau:mpMainInlet
eau:mpToiletCold
eau:mpToiletSink
eau:mpWashingMachine

Pipe configuration c # Classes

URIhttps://w3id.org/eautonome/PipeConfiguration
Description

A pipe configuration, where geometry affects flow measurements.

Super-classessosa:FeatureOfInterest
Memberseau:pipeConfigurationCurved
eau:pipeConfigurationStraight

Shower observing procedure c # Classes

URIhttps://w3id.org/eautonome/ShowerObservingProcedure
Description

Data acquisition for shower via Bluetooth.

Super-classeseau:EautonomeObservingProcedure
Memberseau:showerObservingProcedure

Shower sensor c # Classes

URIhttps://w3id.org/eautonome/ShowerSensor
Description

A sensor attached to a shower head that measures flow rate, volume, temperature, and duration.

Super-classess4watr:WaterDevice
sosa:Sensor
Memberseau:hansaActivejetDigital

Object Properties

has consumption event (Object property) # OPs

URIhttps://w3id.org/eautonome/hasConsumptionEvent
Description

Links an observation collection to the domestic usage activity it represents.

Domain(s)sosa:ObservationCollection
Range(s)eau:ConsumptionEvent
Inverse ofeau:isConsumptionEventOf

has pipe configuration (Object property) # OPs

URIhttps://w3id.org/eautonome/hasPipeConfiguration
Description

Relates a deployment, observing procedure, or observation collection to the pipe configuration.

Domain(s)sosa:Deploymentsosa:ObservingProceduresosa:ObservationCollection
Range(s)eau:PipeConfiguration
Inverse ofeau:isPipeConfigurationOf

is consumption event of (Object property) # OPs

URIhttps://w3id.org/eautonome/isConsumptionEventOf
Description

Links a consumption event to the observation collection that represents it.

Domain(s)eau:ConsumptionEvent
Range(s)sosa:ObservationCollection
Inverse ofeau:hasConsumptionEvent

is location of (Object property) # OPs

URIhttps://w3id.org/eautonome/isLocationOf
Description

Links a domestic room to a measurement point located in that room.

Domain(s)eau:DomesticRoom
Range(s)eau:MeasurementPoint
Inverse ofeau:locatedIn

is measured at (Object property) # OPs

URIhttps://w3id.org/eautonome/isMeasuredAt
Description

Links a water asset to the measurement point that instruments it.

Domain(s)s4watr:WaterAsset
Range(s)eau:MeasurementPoint
Inverse ofeau:measuresOnAsset

is monitored by (Object property) # OPs

URIhttps://w3id.org/eautonome/isMonitoredBy
Description

Static topology link from a measurement point to the sensor that monitors it, independent of any observation.

Domain(s)eau:MeasurementPoint
Range(s)sosa:Sensor
Inverse ofeau:monitors

is pipe configuration of (Object property) # OPs

URIhttps://w3id.org/eautonome/isPipeConfigurationOf
Description

Relates a pipe configuration to a deployment, observing procedure, or observation collection.

Domain(s)eau:PipeConfiguration
Range(s)sosa:Deploymentsosa:ObservingProceduresosa:ObservationCollection
Inverse ofeau:hasPipeConfiguration

is served by (Object property) # OPs

URIhttps://w3id.org/eautonome/isServedBy
Description

Links a domestic room to a measurement point that serves it as water-use endpoint.

Domain(s)eau:DomesticRoom
Range(s)eau:MeasurementPoint
Inverse ofeau:servesEndpoint

located in (Object property) # OPs

URIhttps://w3id.org/eautonome/locatedIn
Description

The room where the measurement point is located.

Domain(s)eau:MeasurementPoint
Range(s)eau:DomesticRoom
Inverse ofeau:isLocationOf

measures on asset (Object property) # OPs

URIhttps://w3id.org/eautonome/measuresOnAsset
Description

The pipe or water asset instrumented at this measurement point.

Domain(s)eau:MeasurementPoint
Range(s)s4watr:WaterAsset
Inverse ofeau:isMeasuredAt

measures water kind (Object property) # OPs

URIhttps://w3id.org/eautonome/measuresWaterKind
Description

Specifies the type of water measured.

Domain(s)eau:MeasurementPoint
Range(s)s4watr:WaterKind
Inverse ofeau:waterKindMeasuredAt

monitors (Object property) # OPs

URIhttps://w3id.org/eautonome/monitors
Description

Static topology link from a sensor to the measurement point it monitors, independent of any observation.

Domain(s)sosa:Sensor
Range(s)eau:MeasurementPoint
Inverse ofeau:isMonitoredBy

serves endpoint (Object property) # OPs

URIhttps://w3id.org/eautonome/servesEndpoint
Description

Connects a measurement point to the room where the water is used.

Domain(s)eau:MeasurementPoint
Range(s)eau:DomesticRoom
Inverse ofeau:isServedBy

water kind measured at (Object property) # OPs

URIhttps://w3id.org/eautonome/waterKindMeasuredAt
Description

Links a water kind to a measurement point where that kind of water is measured.

Domain(s)s4watr:WaterKind
Range(s)eau:MeasurementPoint
Inverse ofeau:measuresWaterKind

Datatype Properties

has analog input (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasAnalogInput
Description

Identifier of the analog input channel used on the ADC.

Domain(s)sosa:Sensor
Range(s)xsd:string

has calibration intercept (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasCalibrationIntercept
Description

Intercept for converting sensor readings to flow values.

Domain(s)sosa:Sensor
Range(s)xsd:decimal

has calibration R2 (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasCalibrationR2
Description

Coefficient of determination for the calibration.

Domain(s)sosa:Sensor
Range(s)xsd:decimal [0.0, 1.0]

has calibration slope (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasCalibrationSlope
Description

Numeric slope used to convert sensor readings to flow values.

Domain(s)sosa:Sensor
Range(s)xsd:decimal

has conductivity equation (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasConductivityEquation
Description

Equation relating sensor current to measured conductivity.

Domain(s)sosa:Sensor
Range(s)xsd:string

has duration in seconds (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasDurationSeconds
Description

Duration of the observation in seconds.

Domain(s)sosa:Observation
Range(s)xsd:decimal

has flow equation (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasFlowEquation
Description

Equation relating sensor current to measured flow rate.

Domain(s)eau:VortexFlowmeter
Range(s)xsd:string

has operational status (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasOperationalStatus
Description

Current status of the system, can be active, inactive, or planned.

Domain(s)sosa:System
Range(s)xsd:string

has sampling period (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasSamplingPeriod
Description

Interval between sensor samples, in seconds.

Domain(s)eau:EautonomeObservingProcedure
Range(s)xsd:decimal

has temperature equation (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasTemperatureEquation
Description

Equation relating sensor current to measured temperature.

Domain(s)sosa:Sensor
Range(s)xsd:string

has transmission interval (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasTransmissionInterval
Description

Time interval between consecutive observation recordings, in seconds.

Domain(s)eau:EautonomeObservingProcedure
Range(s)xsd:decimal

has trigger threshold (Datatype property) # DPs

URIhttps://w3id.org/eautonome/hasTriggerThreshold
Description

Minimum change in the measured quantity that triggers an observation.

Domain(s)eau:EautonomeObservingProcedure
Range(s)xsd:decimal

Named Individuals

Afternoon shower consumptionni

URIhttps://w3id.org/eautonome/obsColAfternoonShower20260628
Class(es)sosa:ObservationCollection
Is Defined Byhttps://w3id.org/eautonome/
DescriptionFlow observations during the afternoon shower period.
sosa:hasFeatureOfInteresteau:mpBathroomHot
sosa:hasUltimateFeatureOfInteresteau:domesticGreywater
sosa:madeBySensoreau:hansaActivejetDigital
sosa:observedPropertys4watr:FlowRate
sosa:usedProcedureeau:showerObservingProcedure
eau:hasConsumptionEventeau:eventAfternoonShower20260628

Afternoon shower eventni

URIhttps://w3id.org/eautonome/eventAfternoonShower20260628
Class(es)eau:ConsumptionEvent
Is Defined Byhttps://w3id.org/eautonome/
DescriptionAn afternoon water consumption event.

Basementni

URIhttps://w3id.org/eautonome/roomBasement
Class(es)eau:DomesticRoom
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA domestic room holding the connection to the cold water supply.

Basement flowmeterni

URIhttps://w3id.org/eautonome/flowmeterBasementCold
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionFlowmeter connected to the main cold water supply via an extended cable.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard1
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN3
eau:hasCalibrationR20.9988
eau:hasCalibrationSlope0.957
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusinactive
eau:monitorseau:mpBasementCold

Basement measurement pointni

URIhttps://w3id.org/eautonome/mpBasementCold
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the basement cold water supply.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomBasement
eau:measuresOnAsseteau:pipeBasementCold
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomBasement

Basement pipeni

URIhttps://w3id.org/eautonome/pipeBasementCold
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionCold water pipe in the basement.
s4watr:isDesignedFors4watr:DrinkingWater

Bathroomni

URIhttps://w3id.org/eautonome/roomBathroom
Class(es)eau:DomesticRoom
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA domestic room primarily used for bathing, sink use, and laundry water consumption.

Bathroom cold water flowmeterni

URIhttps://w3id.org/eautonome/flowmeterBathroomCold
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures cold water flow to the bathroom circuit.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard1
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN0
eau:hasCalibrationR20.9988
eau:hasCalibrationSlope0.957
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusinactive
eau:monitorseau:mpBathroomCold

Bathroom cold water measurement pointni

URIhttps://w3id.org/eautonome/mpBathroomCold
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the bathroom cold water circuit.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomBathroom
eau:measuresOnAsseteau:pipeBathroomCold
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomBathroom

Bathroom cold water pipeni

URIhttps://w3id.org/eautonome/pipeBathroomCold
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionCold water pipe for the bathroom.
s4watr:isDesignedFors4watr:DrinkingWater

Bathroom hot water flowmeterni

URIhttps://w3id.org/eautonome/flowmeterBathroomHot
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures hot water flow to the bathroom circuit.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard1
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN2
eau:hasCalibrationR20.9988
eau:hasCalibrationSlope0.957
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusactive
eau:monitorseau:mpBathroomHot

Bathroom hot water measurement pointni

URIhttps://w3id.org/eautonome/mpBathroomHot
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the bathroom hot water circuit.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomBathroom
eau:measuresOnAsseteau:pipeBathroomHot
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomBathroom

Bathroom hot water pipeni

URIhttps://w3id.org/eautonome/pipeBathroomHot
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionHot water pipe for the bathroom.
s4watr:isDesignedFors4watr:DrinkingWater

Boiler JUMO conductivity/temperature sensorni

URIhttps://w3id.org/eautonome/jumoDigiLineBoiler
Class(es)eau:ConductivityTemperatureSensor
Is Defined Byhttps://w3id.org/eautonome/
DescriptionJUMO digiLine CR sensor for the boiler line.
sosa:forPropertys4watr:Conductivity, s4watr:FlowTemperature
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:Conductivity, s4watr:FlowTemperature
eau:hasAnalogInputAN0, AN1
eau:hasConductivityEquationC = 1.036 * ((I - 4) / 16) * 2000 uS/cm
eau:hasOperationalStatusactive
eau:hasTemperatureEquationT = 1.032 * ((I - 4) / 16) * 100 C
eau:monitorseau:mpHeaterOutput

Capability profile for HANSA Activejet Digitalni

URIhttps://w3id.org/eautonome/capHansaActivejetDigital
Class(es)sosa:ObservationCollection
Is Defined Byhttps://w3id.org/eautonome/
DescriptionSystem capability profile for the HANSA Activejet Digital hand shower.
sosa:hasFeatureOfInteresteau:hansaActivejetDigital
sosa:observedPropertys4watr:FlowRate, s4watr:FlowTemperature, s4watr:FlowVolume

Capability profile for heater output flowmeterni

URIhttps://w3id.org/eautonome/capFlowmeterHeaterOutput
Class(es)sosa:ObservationCollection
Is Defined Byhttps://w3id.org/eautonome/
DescriptionSystem capability profile for the heater output flowmeter.
sosa:hasFeatureOfInteresteau:flowmeterHeaterOutput
sosa:observedPropertys4watr:FlowRate

Cold water main entryni

URIhttps://w3id.org/eautonome/pipeColdWaterEntry
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionEntry pipe for cold water.
s4watr:isDesignedFors4watr:DrinkingWater

Curved pipe configurationni

URIhttps://w3id.org/eautonome/pipeConfigurationCurved
Class(es)eau:PipeConfiguration
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA pipe configuration that includes a bend or elbow.

Domestic greywaterni

URIhttps://w3id.org/eautonome/domesticGreywater
Class(es)s4watr:Water
Is Defined Byhttps://w3id.org/eautonome/
DescriptionGreywater within the system, used as the feature of interest for observations.
sosa:hasPropertys4watr:Conductivity, s4watr:FlowRate, s4watr:FlowTemperature, s4watr:FlowVolume, s4watr:Temperature

Domestic reuseni

URIhttps://w3id.org/eautonome/DomesticReuse
Class(es)s4watr:WaterUse
Is Defined Byhttps://w3id.org/eautonome/
DescriptionWater reused in the household.

eau:obsFlowHeaterOutput20260627T034633ni

URIhttps://w3id.org/eautonome/obsFlowHeaterOutput20260627T034633
Class(es)sosa:Observation
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement of flow rate at the heater output.
sosa:hasFeatureOfInteresteau:mpHeaterOutput
sosa:hasSimpleResult3.8
sosa:hasUltimateFeatureOfInteresteau:domesticGreywater
sosa:madeBySensoreau:flowmeterHeaterOutput
sosa:observedPropertys4watr:FlowRate
sosa:resultTime2026-06-27T03:46:33+02:00
sosa:usedProcedureeau:eautonomeObservingProcedure

eau:obsFlowMainInlet20260627T020617ni

URIhttps://w3id.org/eautonome/obsFlowMainInlet20260627T020617
Class(es)sosa:Observation
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement of flow rate at the main inlet.
sosa:hasFeatureOfInteresteau:mpMainInlet
sosa:hasSimpleResult0.71
sosa:hasUltimateFeatureOfInteresteau:domesticGreywater
sosa:madeBySensoreau:flowmeterMainInlet
sosa:observedPropertys4watr:FlowRate
sosa:resultTime2026-06-27T02:06:17+02:00
sosa:usedProcedureeau:eautonomeObservingProcedure

Eautonome pilot systemni

URIhttps://w3id.org/eautonome/eautonomeSystem
Class(es)eau:GreywaterRecyclingSystem
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA greywater recycling pilot installation located in a residential house in Noisiel.
sosa:hasDeploymenteau:eautonomeDeployment
sosa:hostseau:raspberryPi4
s4watr:isDesignedForeau:Greywater, eau:TreatedGreywater
s4watr:isIntendedFors4watr:Domestic, eau:DomesticReuse
eau:hasOperationalStatusactive

Evening shower eventni

URIhttps://w3id.org/eautonome/eventEveningShower20260627
Class(es)eau:ConsumptionEvent
Is Defined Byhttps://w3id.org/eautonome/
DescriptionAn evening water consumption event.

Gardenni

URIhttps://w3id.org/eautonome/roomGarden
Class(es)eau:DomesticRoom
Is Defined Byhttps://w3id.org/eautonome/
DescriptionAn outdoor domestic area that can receive treated greywater for irrigation.

Greywaterni

URIhttps://w3id.org/eautonome/Greywater
Class(es)s4watr:WaterKind
Is Defined Byhttps://w3id.org/eautonome/
DescriptionDomestic wastewater excluding blackwater.

Hot water heater output pipeni

URIhttps://w3id.org/eautonome/pipeHeaterOutput
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionPipe delivering hot water from the heater.
s4watr:isDesignedFors4watr:DrinkingWater

Kitchenni

URIhttps://w3id.org/eautonome/roomKitchen
Class(es)eau:DomesticRoom
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA domestic room primarily used for cooking and dishwashing.

Kitchen cold water flowmeterni

URIhttps://w3id.org/eautonome/flowmeterKitchenCold
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures cold water flow to the kitchen circuit.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard1
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN7
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusactive
eau:monitorseau:mpKitchenCold

Kitchen cold water measurement pointni

URIhttps://w3id.org/eautonome/mpKitchenCold
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the kitchen cold water circuit.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomKitchen
eau:measuresOnAsseteau:pipeKitchenCold
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomKitchen

Kitchen cold water pipeni

URIhttps://w3id.org/eautonome/pipeKitchenCold
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionCold water pipe for the kitchen.
s4watr:isDesignedFors4watr:DrinkingWater

Kitchen hot water flowmeterni

URIhttps://w3id.org/eautonome/flowmeterKitchenHot
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures hot water flow to the kitchen circuit.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN6
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusactive
eau:monitorseau:mpKitchenHot

Kitchen hot water measurement pointni

URIhttps://w3id.org/eautonome/mpKitchenHot
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the kitchen hot water circuit.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomKitchen
eau:measuresOnAsseteau:pipeKitchenHot
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomKitchen

Kitchen hot water pipeni

URIhttps://w3id.org/eautonome/pipeKitchenHot
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionHot water pipe for the kitchen.
s4watr:isDesignedFors4watr:DrinkingWater

Main inlet flowmeterni

URIhttps://w3id.org/eautonome/flowmeterMainInlet
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
Descriptionifm vortex flowmeter DN10.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN3
eau:hasFlowEquationQ = 2.0 * (I - 4)
eau:hasOperationalStatusactive
eau:monitorseau:mpMainInlet

Main inlet measurement pointni

URIhttps://w3id.org/eautonome/mpMainInlet
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the main cold water entry.
sosa:hasPropertys4watr:FlowRate, s4watr:FlowTemperature
eau:locatedIneau:roomBasement
eau:measuresOnAsseteau:pipeColdWaterEntry
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomBasement

Main inlet temperature sensorni

URIhttps://w3id.org/eautonome/tempSensorMainInlet
Class(es)sosa:Sensor
Is Defined Byhttps://w3id.org/eautonome/
DescriptionTemperature output of the main inlet ifm vortex meter.
sosa:forPropertys4watr:FlowTemperature
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:FlowTemperature
eau:hasAnalogInputAN4
eau:hasOperationalStatusactive
eau:hasTemperatureEquationT = 9.375 * (I - 4) - 25
eau:monitorseau:mpMainInlet

Operating conditions for HANSA Activejet Digitalni

URIhttps://w3id.org/eautonome/condHansaActivejetDigital
Class(es)sosa:ObservationCollection
Is Defined Byhttps://w3id.org/eautonome/
DescriptionNominal shower operation with Bluetooth communication and domestic water flow.
sosa:hasFeatureOfInteresteau:hansaActivejetDigital
sosa:observedPropertys4watr:FlowRate

Operating conditions for heater output flowmeterni

URIhttps://w3id.org/eautonome/condFlowmeterHeaterOutput
Class(es)sosa:ObservationCollection
Is Defined Byhttps://w3id.org/eautonome/
DescriptionNominal operation with domestic hot water flow.
sosa:hasFeatureOfInteresteau:flowmeterHeaterOutput
sosa:observedPropertys4watr:FlowTemperature

Raspberry Pi 4ni

URIhttps://w3id.org/eautonome/raspberryPi4
Class(es)sosa:Platform
Is Defined Byhttps://w3id.org/eautonome/
DescriptionThe computing platform that executes the observing procedure and hosts the analog-to-digital converters.
sosa:hasDeploymenteau:eautonomeDeployment
sosa:hasSubSystemeau:adcCard1, eau:adcCard2
sosa:hostseau:adcCard1, eau:adcCard2
sosa:inDeploymenteau:eautonomeDeployment
sosa:isHostedByeau:eautonomeSystem
eau:hasOperationalStatusactive

Shower JUMO conductivity/temperature sensorni

URIhttps://w3id.org/eautonome/jumoDigiLineShower
Class(es)eau:ConductivityTemperatureSensor
Is Defined Byhttps://w3id.org/eautonome/
DescriptionJUMO digiLine CR sensor for the shower line.
sosa:forPropertys4watr:FlowTemperature
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:FlowTemperature
eau:hasAnalogInputAN5
eau:hasConductivityEquationC = 1.036 * ((I - 4) / 16) * 2000 uS/cm
eau:hasOperationalStatusactive
eau:hasTemperatureEquationT = 1.032 * ((I - 4) / 16) * 100 C
eau:monitorseau:mpBathroomHot

Shower observing procedureni

URIhttps://w3id.org/eautonome/showerObservingProcedure
Class(es)eau:ShowerObservingProcedure
Is Defined Byhttps://w3id.org/eautonome/
DescriptionShower data acquisition via Bluetooth.
sosa:forPropertys4watr:FlowRate, s4watr:FlowTemperature, s4watr:FlowVolume
sosa:implementedByeau:hansaActivejetDigital

Straight pipe configurationni

URIhttps://w3id.org/eautonome/pipeConfigurationStraight
Class(es)eau:PipeConfiguration
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA pipe configuration with a straight section and no bends.

Toiletni

URIhttps://w3id.org/eautonome/roomToilet
Class(es)eau:DomesticRoom
Is Defined Byhttps://w3id.org/eautonome/
DescriptionA domestic room where treated greywater is reused.

Toilet flowmeterni

URIhttps://w3id.org/eautonome/flowmeterToiletCold
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures flow to the toilet.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard1
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN1
eau:hasCalibrationR20.9988
eau:hasCalibrationSlope0.957
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusinactive
eau:monitorseau:mpToiletCold

Toilet measurement pointni

URIhttps://w3id.org/eautonome/mpToiletCold
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point for treated greywater reuse.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomToilet
eau:measuresOnAsseteau:pipeToiletCold
eau:measuresWaterKindeau:TreatedGreywater
eau:servesEndpointeau:roomToilet

Toilet pipeni

URIhttps://w3id.org/eautonome/pipeToiletCold
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionPipe supplying cold water to the toilet.
s4watr:isDesignedFors4watr:DrinkingWater

Toilet sink measurement pointni

URIhttps://w3id.org/eautonome/mpToiletSink
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point on the toilet sink water circuit.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomToilet
eau:measuresOnAsseteau:pipeToiletSink
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomToilet

Toilet sink pipeni

URIhttps://w3id.org/eautonome/pipeToiletSink
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionPipe supplying water to the toilet sink.
s4watr:isDesignedFors4watr:DrinkingWater

Treated greywaterni

URIhttps://w3id.org/eautonome/TreatedGreywater
Class(es)s4watr:WaterKind
Is Defined Byhttps://w3id.org/eautonome/
DescriptionGreywater after treatment.

Washing machine flowmeterni

URIhttps://w3id.org/eautonome/flowmeterWashingMachine
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures water supply to the washing machine.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN2
eau:hasCalibrationR20.9988
eau:hasCalibrationSlope0.957
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusinactive
eau:monitorseau:mpWashingMachine

Washing machine measurement pointni

URIhttps://w3id.org/eautonome/mpWashingMachine
Class(es)eau:MeasurementPoint
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasurement point for water to the washing machine.
sosa:hasPropertys4watr:FlowRate
eau:locatedIneau:roomBathroom
eau:measuresOnAsseteau:pipeWashingMachine
eau:measuresWaterKinds4watr:DrinkingWater
eau:servesEndpointeau:roomBathroom

Washing machine pipeni

URIhttps://w3id.org/eautonome/pipeWashingMachine
Class(es)s4watr:Pipe
Is Defined Byhttps://w3id.org/eautonome/
DescriptionWater pipe supplying the washing machine.
s4watr:isDesignedFors4watr:DrinkingWater

WC sink flowmeterni

URIhttps://w3id.org/eautonome/flowmeterToiletSink
Class(es)eau:VortexFlowmeter
Is Defined Byhttps://w3id.org/eautonome/
DescriptionMeasures flow to the toilet sink.
sosa:forPropertys4watr:FlowRate
sosa:implementseau:eautonomeObservingProcedure
sosa:isHostedByeau:adcCard2
sosa:observess4watr:FlowRate
eau:hasAnalogInputAN7
eau:hasFlowEquationQ = 0.938 * (I - 4)
eau:hasOperationalStatusactive
eau:monitorseau:mpToiletSink

Namespaces

default (eau)
https://w3id.org/eautonome/
dcterms
http://purl.org/dc/terms/
erdemonal
https://w3id.org/people/erdemonal/
owl
http://www.w3.org/2002/07/owl#
qudt
http://qudt.org/schema/qudt/
rdf
http://www.w3.org/1999/02/22-rdf-syntax-ns#
rdfs
http://www.w3.org/2000/01/rdf-schema#
s4watr
https://saref.etsi.org/saref4watr/
saref
https://saref.etsi.org/core/
schema
http://schema.org/
sosa
http://www.w3.org/ns/sosa/
time
http://www.w3.org/2006/time#
unit
http://qudt.org/vocab/unit/
vann
http://purl.org/vocab/vann/
xsd
http://www.w3.org/2001/XMLSchema#

Legend

c Classes
op Object Properties
fp Functional Properties
dp Data Properties
ap Annotation Properties
p Properties
ni Named Individuals

Table of Contents